  • How To Store Lead-Acid Batteries? —Yeeu Power
    Nov 27, 2024
    Storing lead acid batteries properly is important to maintain their performance and prolong their lifespan. Here are some guidelines for storing from professional lead-acid battery manufacturer:     Choose a cool and dry storage location: Lead-acid batteries should be stored in a cool, dry area with a stable temperature between 0°C and 25°C (32°F and 77°F). Avoid storing them in extreme temperatures or exposed to direct sunlight.   Fully charge the batteries: Before storing lead-acid batteries, ensure they are fully charged. This helps prevent sulfation and maintains the battery's capacity. If the batteries are not fully charged, they may self-discharge over time.   Disconnect or maintain a float charge: If the batteries are connected to a device or equipment, disconnect them before storage. Alternatively, you can maintain a float charge by using a battery maintainer or charger specifically designed for float charging. This helps prevent self-discharge and keeps the battery at an optimal charge level.   Clean the battery terminals: Ensure the battery terminals are clean and free from corrosion. Use a mixture of baking soda and water or a battery terminal cleaner to remove any dirt or corrosion. Dry the terminals before storage.   Inspect and maintain the electrolyte level: For flooded lead-acid batteries, check the electrolyte level and top it off if necessary. Use distilled water to fill the cells, if needed. Follow the vrla battery manufacturer's guidelines for proper electrolyte level maintenance.   Store in an upright position: Sealed lead-acid batteries should be stored upright to prevent acid leakage. Make sure they are securely placed and won't tip over during storage.   Regularly check the battery: Periodically inspect the batteries during storage to ensure they are in good condition. Check for any signs of damage, leakage, or swelling. If you notice any issues, consult the sla battery manufacturer or replace the battery if needed.   By following these storage guidelines, you can ensure that lead-acid batteries are kept in optimal condition and are ready for use.
    Read More
  • How To Charge A Lead-Acid Battery Properly?
    Dec 20, 2024
    There're quite a few people have trouble on how to properly charge the Lead-Acid Batteries, this blog will guide you and let you know the best steps and pratices.     Choose the Right Charger Select a charger that is designed for your specific type of lead acid battery, whether it's flooded batteries, AGM (Absorbed Glass Mat) batteries, or gel batteries. Each type has different charging requirements regarding voltage and current levels.   Connect Charger Connect the charger's positive (red) clip to the positive terminal of the battery and the negative (black) clip to the negative terminal. Ensure a secure and proper connection.   Multi-Stage Charging: Lead acid batteries should be charged in multiple stages, including bulk charging, absorption charging, and float charging. Smart chargers with microprocessors can automate this process and adjust the current and voltage as required for an optimal charge.   Set Charging Parameters Refer to the vrla battery manufacturer's recommendations for the charging voltage and current settings. Set the charger accordingly to avoid overcharging or undercharging.   Bulk Charging This stage delivers the highest current to rapidly bring the battery up to about 80% of its full capacity. The voltage rises until it reaches a pre-set limit based on the battery type.   Absorption Charging Once the battery reaches the predefined voltage, it enters the absorption charge stage. The current tapers off while the charger maintains a steady voltage, topping off the remaining 20% of the battery’s charge.   Float Charging After the battery is fully charged, the charger switches to the float charge stage, maintaining the battery’s charge without overloading it. The voltage is reduced to a lower level to keep the battery topped up without producing gas or excessive heat.   Safety Precautions Always charge lead acid batteries in a well-ventilated area to prevent the buildup of gases, such as hydrogen, which is highly flammable. Hydrogen gas can accumulate and become hazardous if not properly ventilated.   Temperature Control Ideally, lead acid batteries should be charged at temperatures below 80°F (27°C). Charging at high temperatures can lead to thermal runaway, where the battery overheats and becomes damaged.   Avoid Overcharging Overcharging a lead acid battery can shorten its lifespan by producing excess gas and leading to a loss of electrolyte in flooded batteries and increased internal pressure in sealed AGM batteries and gel batteries. Use smart chargers that automatically adjust the charging current and voltage based on the battery’s state of charge.   Regular Maintenance For flooded lead acid batteries, regularly check and maintain the proper electrolyte levels to ensure optimal performance. Inspect the battery terminals for any corrosion or buildup. Clean the terminals if necessary and ensure they are tightly connected.   Charge After Each Use To maximize battery lifespan, charge the battery after each use.   Remember, proper charging is essential to maintain the performance and longevity of a lead acid battery. Follow the lead acid battery manufacturer's instructions and guidelines for your specific battery model to ensure safe and effective charging.    
    Read More

leave a message

leave a message
If you are interested in our products and want to know more details, please leave a message here,we will reply you as soon as we can.
submit

Home

Products

WhatsApp

contact